Galvanic-submerged photosynthesis of crystallites: Fabrication of ZnO nanorods@ Cu-surface

Y Takahashi, K Hiraiwa, M Jeem, L Zhang… - Applied surface …, 2019 - Elsevier
… In this study, 1-D ZnO NRs were successfully fabricated on a Cu plate surface by initiating
a galvanic contact reaction between Zn@Cu surface in a submerged photo-synthesis of …

Alteration, adsorption and nucleation processes on clay–water interfaces: mechanisms for the retention of uranium by altered clay surfaces on the nanometer scale

M Schindler, CA Legrand, MF Hochella Jr - Geochimica et Cosmochimica …, 2015 - Elsevier
… the outline of the site (higher density of contour lines); the area contaminated by U- and
sulfuric acid bearing solutions is shaded in grey; sampling location for contact pH measurement

[HTML][HTML] LED-CT scan for pH distribution on a cross-section of cell culture medium

N Higashino, T Takayama, H Ito, M Horade… - Sensors, 2018 - mdpi.com
… For observing the results under 100% absorbance at the surface, we made a non-transparent …
Under 100% observation at the surface, we resultantly obtain the outline of the sample as …

A U-shape fibre-optic pH sensor based on hydrogen bonding of ethyl cellulose with a sol-gel matrix

Z Tang, D Gomez, C He, S Korposh… - Journal of Lightwave …, 2021 - opg.optica.org
… high stability, porosity and surface area, which are beneficial to … the silanols determine the
surface acidity and modulate the … al., “Optical non-contact pH measurement in cell culture with …

Development of Non-Invasive Deep Tissue pH Sensor.

R Micheels… - … Star Technologies Inc …, 1995 - apps.dtic.mil
… , insensitivity to probe height from skin/muscle surface, and a measurement time of under 15
… Diagram of near-infrared fiber-optic spectroscopy systemn for non-contact pH measurement

Development of an iridium-based pH sensor for bioanalytical applications

S Bause, M Decker, F Gerlach, J Näther… - Journal of Solid State …, 2018 - Springer
… The fabrication of the sensor was carried out by a two-stage coating process of different
iridium solutions on a platinum thick film surface. The pH response behaviour and the Nernstian …

Modular instrumentation for controlling and monitoring in-vitro cultivation environment and image-based functionality measurements of human stem cells

D Kattipparambil Rajan - 2020 - trepo.tuni.fi
… In this context, we devised the noncontact pH measurement system MO-pH, using 3D printed
sterilisable-modular components. For MO-pH, an improvised pH translational model was …

A comparison of paper in identical copies of books

RD SMITH - 1972 - degruyter.com
surfaces, the smaller of which has an area of approximately 0.25 square inches (160 sq.
mm.)«.… on which to evaluate the applicability of contact pH measurement to older book papers. …

Nanomaterials for intracellular pH sensing and imaging

Y Lian, W Zhang, L Ding, X Zhang, Y Zhang… - Novel nanomaterials for …, 2019 - Elsevier
… For example, by using improved acid-base titration method, the surface acid/base
amount on the surface of living marine alga cells could be accurately measured [17]. …

Transmitted light pH optode for small sample volumes

C Rogge, S Zinn, P Prosposito… - Journal of Sensors …, 2017 - jsss.copernicus.org
… of the chambers resulting in slightly different surfaces (flatness, roughness, micro-scratches …
Optical non-contact pH measurement in cell culture with sterilizable, modular parts, Talanta, …