Galvanic-submerged photosynthesis of crystallites: Fabrication of ZnO nanorods@ Cu-surface
Y Takahashi, K Hiraiwa, M Jeem, L Zhang… - Applied surface …, 2019 - Elsevier
… In this study, 1-D ZnO NRs were successfully fabricated on a Cu plate surface by initiating
a galvanic contact reaction between Zn@Cu surface in a submerged photo-synthesis of …
a galvanic contact reaction between Zn@Cu surface in a submerged photo-synthesis of …
Alteration, adsorption and nucleation processes on clay–water interfaces: mechanisms for the retention of uranium by altered clay surfaces on the nanometer scale
M Schindler, CA Legrand, MF Hochella Jr - Geochimica et Cosmochimica …, 2015 - Elsevier
… the outline of the site (higher density of contour lines); the area contaminated by U- and
sulfuric acid bearing solutions is shaded in grey; sampling location for contact pH measurement …
sulfuric acid bearing solutions is shaded in grey; sampling location for contact pH measurement …
[HTML][HTML] LED-CT scan for pH distribution on a cross-section of cell culture medium
N Higashino, T Takayama, H Ito, M Horade… - Sensors, 2018 - mdpi.com
… For observing the results under 100% absorbance at the surface, we made a non-transparent …
Under 100% observation at the surface, we resultantly obtain the outline of the sample as …
Under 100% observation at the surface, we resultantly obtain the outline of the sample as …
A U-shape fibre-optic pH sensor based on hydrogen bonding of ethyl cellulose with a sol-gel matrix
… high stability, porosity and surface area, which are beneficial to … the silanols determine the
surface acidity and modulate the … al., “Optical non-contact pH measurement in cell culture with …
surface acidity and modulate the … al., “Optical non-contact pH measurement in cell culture with …
Development of Non-Invasive Deep Tissue pH Sensor.
R Micheels… - … Star Technologies Inc …, 1995 - apps.dtic.mil
… , insensitivity to probe height from skin/muscle surface, and a measurement time of under 15
… Diagram of near-infrared fiber-optic spectroscopy systemn for non-contact pH measurement …
… Diagram of near-infrared fiber-optic spectroscopy systemn for non-contact pH measurement …
Development of an iridium-based pH sensor for bioanalytical applications
S Bause, M Decker, F Gerlach, J Näther… - Journal of Solid State …, 2018 - Springer
… The fabrication of the sensor was carried out by a two-stage coating process of different
iridium solutions on a platinum thick film surface. The pH response behaviour and the Nernstian …
iridium solutions on a platinum thick film surface. The pH response behaviour and the Nernstian …
Modular instrumentation for controlling and monitoring in-vitro cultivation environment and image-based functionality measurements of human stem cells
D Kattipparambil Rajan - 2020 - trepo.tuni.fi
… In this context, we devised the noncontact pH measurement system MO-pH, using 3D printed
sterilisable-modular components. For MO-pH, an improvised pH translational model was …
sterilisable-modular components. For MO-pH, an improvised pH translational model was …
A comparison of paper in identical copies of books
RD SMITH - 1972 - degruyter.com
… surfaces, the smaller of which has an area of approximately 0.25 square inches (160 sq.
mm.)«.… on which to evaluate the applicability of contact pH measurement to older book papers. …
mm.)«.… on which to evaluate the applicability of contact pH measurement to older book papers. …
Nanomaterials for intracellular pH sensing and imaging
Y Lian, W Zhang, L Ding, X Zhang, Y Zhang… - Novel nanomaterials for …, 2019 - Elsevier
… For example, by using improved acid-base titration method, the surface acid/base
amount on the surface of living marine alga cells could be accurately measured [17]. …
amount on the surface of living marine alga cells could be accurately measured [17]. …
Transmitted light pH optode for small sample volumes
C Rogge, S Zinn, P Prosposito… - Journal of Sensors …, 2017 - jsss.copernicus.org
… of the chambers resulting in slightly different surfaces (flatness, roughness, micro-scratches …
Optical non-contact pH measurement in cell culture with sterilizable, modular parts, Talanta, …
Optical non-contact pH measurement in cell culture with sterilizable, modular parts, Talanta, …