ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Rebreathed Fraction of Air
Source:
2
https://tinyurl.com/rebreathed-air-fraction
maintained by: Twitter:@DavidElfstrom
3
420
Co = Outdoor Air CO₂ ppm (note Aranet4 meter calibrates to 420 ppm)
4
38000
Ca = Volume fraction of CO₂ added to exhaled breath (ppm)
5
6
Indoor ppmFraction 1 in X breaths
7
5000.2%475
8
6000.5%211
9
7000.7%136
10
8001.0%100
11
9001.3%79
12
10001.5%66
13
11001.8%56
https://doi.org/10.1034/j.1600-0668.2003.00189.x
14
12002.1%49
Risk of indoor airborne infection transmission estimated from carbon dioxide concentration
15
13002.3%43
S. N. Rudnick, D. K. Milton, Indoor Air, Volume 13, Issue 3, September 2003, p237-245
16
14002.6%39
17
15002.8%35
18
16003.1%32
Reasonable approximation
19
17003.4%30
Based on 40,000 ppm in breath and 400 ppm outdoor air:
20
18003.6%28
For every additional 400 ppm over outdoor, rebreathed fraction increases 1%
21
19003.9%26Indoor CO₂ ppmRebreathed1 in X breaths
22
20004.2%244000%None
23
22004.7%218001%100
24
24005.2%1912002%50
25
26005.7%1716003%33
26
28006.3%1620004%25
27
30006.8%1524005%20
28
32007.3%1428006%17
29
34007.8%1332007%14
30
36008.4%1236008%13
31
38008.9%1140009%11
32
40009.4%11440010%10
33
42009.9%10480011%9
34
440010.5%10520012%8
35
460011.0%9
36
480011.5%9
37
500012.1%8
⬅ occupational health limit for CO2 exposure (such as for an industrial process using CO2 gas): 5000 ppm, 8-hour time-weighted average
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100